22KW inverter VSD VFD 220V VARIABLE FREQUENCY DRIVE INVERTER
220V single phase in and 3 phase out motors less than 45 amps
Excellent quality high performance variable speed drive which can vary the speed of 1 phase motors. With a wide range of sizes starting from 0.75 kW up to 75 kW
Start overloading has been increased to 200% for 1s
Download Operation Manual
For three phase motors go here...
Item |
Technical Index |
Specification |
Input |
Input voltage |
1AC 220~240V±15% |
Input frequency |
50/60Hz±5% |
|
Output |
Output voltage |
0~rated input voltage |
Output frequency |
0~6000Hz |
|
Control Features |
Control mode |
V/f control |
Operation command mode |
Keypad control |
|
Frequency setting mode |
Digital setting, analog setting, pulse frequency setting, |
|
Overload capacity |
150% / 120s, 160% / 60s, 180% / 10s, 200% / 1s. |
|
Starting torque |
0.5Hz/180% (SVC); 1Hz/150% (V/f) |
|
Speed control precision |
±0.5% (SVC) |
|
Carrier frequency |
0.5~16.0kHz, automatically adjusted according to |
|
Frequency accuracy |
Digital setting: 0.01Hz |
|
Torque boost |
Automatically torque boost; manually torque boost: |
|
V/f curve |
Three types: linear, multiple point and square type |
|
Acceleration/deceleration mode |
Straight line/S curve; four kinds of acceleration/deceleration |
|
Braking unit |
build-in standard. |
|
DC braking |
DC braking when starting and stopping |
|
Jog operation |
Jog operation frequency: 0.0Hz~maximum frequency |
|
Simple PLC & multi-step speed operation |
It can realize a maximum of 16 multi-step speeds running via |
|
Built-in PID |
Built-in PID control to easily realize the close loop control of |
|
Automatic voltage regulation |
Keep output voltage constant automatically when input |
|
Control Function |
Torque control |
Torque control without PG |
Wobble frequency control |
Multiple triangular-wave frequency control, special for textile |
|
Timing/length/ |
Timing/length/counting control function |
|
Over-voltage & over-current stall control |
Limit current & voltage automatically during the running |
|
Fault protection function |
Comprehensive protections include over-current, over- |
|
Input/output terminals |
Input terminals |
Programmable digital input: 7 multifunctional inputs, one can be work as high speed pulse input. |
Output terminals |
2 relay outputs, |
|
Communication terminals |
Build-in standard RS485 communication interface, support |
|
Human machine interface |
LED display |
Display frequency setting, output frequency, output voltage, |
Environment |
Ambient temperature |
-10~50°C, without direct sunshine. |
Humidity |
90%RH or less (non-condensing) |
|
Altitude |
≤1000M: output rated power, >1000M: output derated |
|
Storage temperature |
-20~60°C |
We Also Recommend