The magnetic flow meter, also technically an electromagnetic flow meter or more commonly just called a mag flow meter. A magnetic field is applied to the metering tube, which results in a potential difference proportional to the flow velocity perpendicular to the flux lines. The physical principle at work is electromagnetic induction. The magnetic flow meter requires a conducting fluid, for example, water that contains ions, and an electrical insulating pipe surface, for example, a rubber-lined steel tube.

Sizes available from 10mm - 1200mm ID pipe.

Download MIK-LDG electromagnetic flowmeter Data Sheet

Download MIK-LDG electromagnetic flowmeter User Manual 

Product Specification
Technical Performance Parameters
Diameter Nominal DN10 ~ DN1000
Nominal Pressure 0.6~4.0MPa(special pressure can be made to)
Accuracy ±0.3%, ±2mm/s (flow rate < 1m/s)
Liner material PFA,F46,Neoprene,PTFE, FEP
Electrode material Stainless steel SUS316, Hastelloy C, Titanium, Tantalum Platinum-iridium
Medium Temperature Integral type -10℃~+80℃
Split type -25 -180℃
Ambient Temperature -10℃~60℃
Medium Electrical conductivity water 20uS/cm other medium 5uS/cm
Structure type  Integral type, split type
Protection Class IP65,IP68(optional)
Product Standard JB/T 9248-1999 Electromagnetic Flowmeter

Lining 

material

Main Performance Applications
Teflon 1.The most steady material in plastics which is resistible to boiling hydrochloric
acid, vitriolandqua fortis as well as strong alkali and organic impregnates.        
2.Not be perfect in abrasion resistance.
Strong corrosive mediums such 
as strong acid and alkali
PFA Having the same abrasion resistance with PTFE.
Having strong ability of load pressure resistance.
Applicable in state of load pressure
F46

1.Have the same abrasion resistance with 

PTFE.

2.Resistable for low abrasion.

3.Having strong resistance to load pressure.

  1.The same as PTFE.2.Applicable 
in mediums of low abrasion.
 Neoprene

 1.Be of good elasticity,retractility and abrasion

 resistance.
2.Be resistant to low aicd,alkali and salt but 

not for oxidation mediums.

Water,sewage and slurry,mineral 
serosity of low abrasion.
Polyurethane

1.Be of good abrasion resistibility.
2.Not be perfect in acid/alkali resistance.
3.Can't be used for water mixed with organic            

impregnates.

Applicable in mineral serosity,slurry 
and coal slurry of high abrasion.
How to choose the electrode materials
Electrode material Applications
Stainless steel SUS316 Applicable in water,sewage and corrosive mediums.Widely used in industries of petrol,
chemistry,carbamide,etc
Stainless steel
covered with tungsten carbide
Applicable in mediums of no corrosive and low abrasion.
  Hastelloy B(HB) Having strong resistance to hydrochloric acid of any consistency which is below boiling 
waypoint. Also resistable against vitriol,phosphate,hydrofluoric acid,organic acid etc which 
are oxidizable  acid,alkali and non-oxidable salt.
Hastelloy C(HC) Be resistant to oxidable acid such as nitric acid,mixed acid as well as oxidable salt such as
 Fe+++,Cu++and sea water
Titanium Applicable in seawater,and kinds of chloride,hypochlorite salt,oxidable acid(including
fuming  nitric acid),organic acid,alkali etc.Not resistant to a pure reducing acid(such as 
sulphuric acid,hydrochloric acid)corrosion.But if acid contains antioxidant(such as 
Fe+++,Cu++)is greatly  reduce corrosion.
Da In addition to hydrofluoric acid, fuming sulfuric acid, alkali remaining outside chemicals, 
including boiling hydrochloric acid
Platinum-iridium Almost be applicable in all chemical mediums except for aqua fortis,ammonium salt.
Integrated type
Caliber(mm) Size Weight(kg)
L W H
10 150 90 165 3.5
15 150 95 190 3.5
20 150 105 190 4
25 150 115 190 4.3
32 200 140 190 4.6
40 200 150 190 5.1
50 200 165 195 7.4
65 200 185 225 8.1
80 200 200 245 9.8
100 200 220 255 12.2
125 250 250 285 15.4
150 250 285 315 22.1
200 300 340 370 30.2
250 350 395 435 41
300 400 445 475 56
350 450 505 545 76
400 450 565 595 95
450 450 615 640 110
500 500 670 695 120
600 600 780 805 159
700 700 860 885 239
800 800 975 985 418
900 900 1075 1085 539
1000 1000 1175 1185 666
1200 1200 1405 1415 856
Split type
caliber(mm) Size Weight(kg)
L W H
10 150 90 290 6
15 150 95 315 6
20 150 105 315 6.5
25 150 115 315 6.8
32 200 140 315 7.1
40 200 150 315 7.6
50 200 165 320 9.9
65 200 185 350 10.6
80 200 200 365 12.3
100 200 220 380 14.7
125 250 250 410 17.9
150 250 285 440 24.6
200 300 340 495 32.7
250 350 395 560 43.5
300 400 445 600 58
350 450 505 670 78
400 450 565 720 97
450 450 615 765 110
500 500 670 820 122
600 600 780 930 161
700 700 860 1010 241
800 800 975 1110 420
900 900 1075 1210 541
1000 1000 1175 1310 668
1200 1200 1405 1540  
Flow form
  Q100% unit m3/h
V[m/s] 0.3 1 3 7
DN[mm] Minimum Flow Common Flow Maximum Flow
2.5 0.01 0.02 0.05 0.14
4 0.01 0.05 0.14 0.35
6 0.03 0.1 0.31 0.7
10 0.08 0.28 0.85 1.96
20 0.34 1.13 3.39 7.91
25 0.53 1.77 5.3 12.39
32 0.87 2.9 8.69 20.27
40 1.36 4.52 13.57 31.67
50 2.12 7.07 21.21 49.48
65 3.58 11.95 35.84 83.62
80 5.43 18.1 54.29 126.67
100 8.48 28.27 84.82 197.92
125 13.25 44.18 132.54 309.25
150 19.09 63.62 190.85 445.32
200 33.93 113.1 339.3 791.7
250 53.01 176.71 530.13 1236.97
300 76.34 254.47 763.41 1781.29
350 103.91 346.36 1039.08 2424.52
400 135.72 452.39 1357.17 3166.73
500 212.06 706.86 2120.58 4948.02
600 305.37 1017.9 3053.7 7125.3
700 415.62 1385.4 4156.2 9697.8
800 542.88 1809.6 5428.8 12667.2
900 687.06 2290.2 6870.6 16031.4
1000 848.22 2827.4 8482.2 19791.8